11.PositionthenewAnyRAIDadapternearthebackplane.Then,carefullypressthenewAnyRAIDadapter
straightintotheAnyRAID-adapterslotsuntilitissecurelyseated.Tightenthetwoscrewstosecurethe
newAnyRAIDadapterinplace.
Figure127.InstallingtheAnyRAIDadapter
12.ReinstalltheAnyRAID-adapterairduct(ifavailable).
13.Reconnectthecables.See“Connectingcables”onpage41.
Whattodonext:
Toworkwithanotherpieceofhardware,gototheappropriatesection.
Tocompletethereplacementprocedure,goto“Completingthepartsreplacement”onpage175
.
Replacingthehot-swap-drivebackplane
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”
onpageiii
and“Guidelines”onpage67.
Thistopicappliesonlytoservermodelsthathavehot-swapinternalstoragedrivesinstalled.
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Notes:
Thehot-swap-drivebackplaneissensitivetoESD.Ensurethatyoureadandunderstand“Handling
static-sensitivedevices”onpage68firstandcarefullyperformtheoperation.
Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.
Useanydocumentationthatcomeswiththenewhot-swap-drivebackplaneandfollowthoseinstructions
inadditiontotheinstructionsinthistopic.
Toreplacethehot-swap-drivebackplane,dothefollowing:
160ThinkServerTD350UserGuideandHardwareMaintenanceManual