Loading...
Figure 57. Connecting cables to the drives and convertor kit
Cable From the system board To the drives and convertor kit
HDD fan cable
1 HDD fan connector 8 HDD fan on the rear of the HDD and
slim ODD kit
1-to-3 power cable
2 or 3 4-pin power connector 6 and 9 Power connectors on the slim
optical drive and storage drive
Signal cable
4 SATA connector 4 10 Signal connector on the storage drive
Signal cable
5 SATA connector 5 7 Signal connector on the slim optical
drive
Notes:
If your server already has a storage drive installed in drive bay 4, use the 1-to-2 fan power converter
cable to connect the HDD fans. Connect connector
2 to the system board, and connect connectors
1 to the HDD fan cables respectively.
The 1-to-3 power cable provides three SATA power connectors 1 , 2 , and 3 . You can use any two of
the SATA connectors to connect the slim optical drive and storage drive.
If your server has no drive installed in drive bay 3, connect the signal cable from the storage drive to
the SATA connector 3 on the system board. See “System board components” on page 19.