EasyManua.ls Logo

Lenovo ThinkSystem SE350 V2 - Page 105

Lenovo ThinkSystem SE350 V2
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Complete the following steps:
1. Check the Support Portal(http://support.lenovo.com/)for service bulletins and TECH tips and
firmware update related to your drive.
2. Check for any other RAID-related error.
3. Replace the drive.
FQXSPSD0002G: Failure Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: System - Predicted Failure
SNMP Trap ID: 27
CIM Prefix: PLAT CIM ID: 0168
User Action:
Replace hard disk drive 0 at the next maintenance period.
FQXSPSD0002L: Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has a fault.
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0164
User Action:
Complete the following steps:
1. Check the Support Portal(http://support.lenovo.com/)for service bulletins and TECH tips and
firmware update related to your drive.
2. Check for any other RAID-related error.
3. Replace the drive.
FQXSPSD0003G: Failure Predicted on drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: System - Predicted Failure
SNMP Trap ID: 27
CIM Prefix: PLAT CIM ID: 0168
User Action:
Replace hard disk drive 0 at the next maintenance period.
FQXSPSD0003I: Hot Spare enabled for [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Chapter 2. XClarity Controller events 101

Related product manuals