Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required
FQXSPSD0005I: Hot Spare enabled for drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required
FQXSPSD0005L: Array [ComputerSystemElementName] is in critical condition.
This message is for the use case when an implementation has detected that an Array is Critical.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0174
User Action:
Replace the hard disk drive that is indicated by a lit status LED.
FQXSPSD0006L: Array [ComputerSystemElementName] has failed.
This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0176
User Action:
Complete the following steps:
1. Replace any hard disk drive that is indicated by a lit status LED.
2. Re-create the array.
3. Restore the data from a backup.
FQXSPSD0007I: Rebuild in progress for Array in system [ComputerSystemElementName].