1. Replace any hard disk drive that is indicated by lit status.
2. Recreate the array.
3. Restore the date from backup.
FQXSPSD0006L: Array [ComputerSystemElementName] has failed.
This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0176
User Action:
Complete the following steps:
1. Replace any hard disk drive that is indicated by lit status.
2. Recreate the array.
3. Restore the date from backup.
FQXSPSD0007I: Rebuild in progress for Array in system [ComputerSystemElementName].
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0178
User Action:
Information only; no action is required.
FQXSPSD2000I: The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Drive has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0163
User Action:
Information only; no action is required.
FQXSPSD2001I: The [StorageVolumeElementName] has been enabled.
This message is for the use case when an implementation has detected a Drive was Enabled.
Severity: Info
Serviceable: No
Chapter 2. XClarity Controller events 97