Table 4. Events organized by severity (continued)
Event ID
Message String Severity
FQXPMVD0012K Failed to set the TPM/TPM card/TCM policy Warning
FQXPMEM0001M Unable to locate LXPM firmware image Error
FQXPMEM0006M Unable to locate diagnostic firmware image Error
FQXPMEM0007M Diagnostic image cannot be launched as "Console Redirection" is
enabled
Error
FQXPMEM0008M
Diagnostic image cannot be launched as the image may be corrupt Error
FQXPMEM0009M Unexpected error occur Error
FQXPMSD0001M HDD Test was interrupted by the host with a hardware or software
reset
Error
FQXPMSD0002M A fatal error or unknown test error occurred while the device was
executing its self-test
Error
FQXPMSD0003M self-test completed having a test element that failed and the test
element that failed is not known.
Error
FQXPMSD0004M self-test completed having the electrical element of the test failed. Error
FQXPMSD0005M self-test completed having the servo (and/or seek) test element of the
test failed.
Error
FQXPMSD0006M self-test completed having the read element of the test failed. Error
FQXPMSD0007M Hard Drive(s) not found
Error
FQXPMSD0008M UEFI is not ready for LXPM to send command to test hard drive. Error
FQXPMSD0009M
Device error is occurred when LXPM send command to test hard
drive.
Error
FQXPMSD0010M uEFI is timeout while LXPM send command to test hard drive. Error
FQXPMSD0011M
The hard drive is not supported by uEFI while LXPM send command
to test hard drive.
Error
FQXPMUP0201M BMC communication failed: EMMC2USB mount failure. Failed to
update the firmware
Error
FQXPMUP0202M Transfer the update package error. Failed to update the firmware Error
FQXPMUP0203M BMC communication failed: EMMC2USB unmount failure. Failed to
update the firmware
Error
FQXPMUP0204M BMC communication failed: Execute the update cmd failure. Failed to
update the firmware
Error
FQXPMUP0205M BMC communication failed: Get the update status failure.Failed to
update the firmware
Error
FQXPMUP0206M The level of the update package is too old. Failed to update the
firmware.
Error
FQXPMUP0207M The update package is invalid. Failed to update the firmware. Error
FQXPMUP0208M Failed to execute reboot BMC command Error
List of XClarity Provisioning Manager events