2. Re-insert SATA Drive to ensure it is fully connected to the backplane.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
FQXSFIO0005I: An intra-board UPI has been disabled on the link between processor [arg1] port
[arg2] and processor [arg3]port [arg4] because of UPI topology downgrade.
Severity: Info
User Action:
Complete the following steps:
1. This event should be followed by a recent FQXSFIO0005M / FQXSFIO0006M event denoting some
UPI links failure which caused UPI topology downgrade.
2. Solve the event FQXSFIO0005M / FQXSFIO0006M at first, then this event should be solved
automatically.
3. If no recent or after fixing FQXSFIO0005M / FQXSFIO0006M event, this event still persists, collect
Service Data logs.
4. Contact Lenovo Support.
FQXSFIO0005M: An intra-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
error.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
FQXSFIO0006I: An inter-board UPI has been disabled on the link between processor [arg1] port
[arg2] and processor [arg3]port [arg4] because of UPI topology downgrade.
Severity: Info
User Action:
Complete the following steps:
1. This event should be followed by a recent FQXSFIO0005M / FQXSFIO0006M event denoting some
UPI links failure which caused UPI topology downgrade.
2. Solve the event FQXSFIO0005M / FQXSFIO0006M at first, then this event should be solved
automatically.
3. If no recent or after fixing FQXSFIO0005M / FQXSFIO0006M event, this event still persists, collect
Service Data logs.
4. Contact Lenovo Support.
FQXSFIO0006M: An inter-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this