EasyManua.ls Logo

Lenovo ThinkSystem SR650 V2 - Page 149

Lenovo ThinkSystem SR650 V2
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
FQXSFIO0007M: An error has been detected by the IIO on Bus [arg1]. The value of Global Fatal
Error Status register is [arg2]. The value of Global Non-Fatal Error Status register is [arg3]. Please
check error logs for additional downstream device error data.
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
FQXSFIO0008M: An intra-board UPI dynamic link width reduction has been detected on the link
between processor [arg1] port [arg2] and processor [arg3] port [arg4].
Severity: Warning
User Action:
Complete the following steps:
1. Reboot the system.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
FQXSFIO0009M: An inter-board UPI dynamic link width reduction has been detected on the link
between processor [arg1] port [arg2] and processor [arg3] port [arg4].
Severity: Warning
User Action:
Complete the following steps:
1. Reboot the system.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
FQXSFIO0010M: An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The physical [arg6] number
is [arg7].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this device and/or any attached cables were recently installed, moved, serviced or upgraded.
a. Reseat adapter or disk and any attached cables.
b. Reload Device Driver.
Chapter 3. UEFI events 145