Table 2. Events organized by severity (continued)
Event ID
Message String Severity
FQXSPUN2019I Sensor [SensorElementName] has transitioned to a less severe state
from critical.
Informational
FQXSPUN2020I Sensor [SensorElementName] has deasserted the transition to non-
recoverable from a less severe state.
Informational
FQXSPUN2023I Sensor [SensorElementName] has deasserted the transition to non-
recoverable.
Informational
FQXSPUN2050I The RAID controller in PCI slot [arg1] is no longer in critical status. Informational
FQXSPUN2057I The RAID controller in PCI slot [arg1] has a battery now. Informational
FQXSPUP0002I A firmware or software change occurred on system
[ComputerSystemElementName].
Informational
FQXSPUP4001I Flash of [arg1] from [arg2] succeeded for user [arg3] . Informational
FQXSPUP4002I Flash of [arg1] from [arg2] failed for user [arg3]. Informational
FQXSPUP4006I Auto promote primary XCC to backup is [arg1] by user [arg2] from
[arg3] at IP address [arg4].
Informational
FQXSPWD0000I Watchdog Timer expired for [WatchdogElementName]. Informational
FQXSPWD0001I Reboot of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0002I Powering off system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0003I Power cycle of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0004I Watchdog Timer interrupt occurred for [WatchdogElementName]. Informational
FQXSPBR4001I Running the backup Management Controller [arg1] main application. Warning
FQXSPCA0007J Numeric sensor [NumericSensorElementName] going high (upper
non-critical) has asserted.
Warning
FQXSPDM4002I Device [arg1] VPD is not valid. Warning
FQXSPEA0001J Sensor [SensorElementName] has transitioned from normal to non-
critical state.
Warning
FQXSPIO0014J Bus [SensorElementName] is operating in a degraded state.
Warning
FQXSPMA0010J [PhysicalMemoryElementName] on Subsystem
[MemoryElementName] Throttled.
Warning
FQXSPNM4010I DHCP[[arg1]] failure, no IP address assigned. Warning
FQXSPNM4032I DHCPv6 failure, no IP address assigned.
Warning
FQXSPPP4009I The measured power value exceeded the power cap value. Warning
FQXSPPP4010I The new minimum power cap value exceeded the power cap value. Warning
FQXSPPU0002G The Processor [ProcessorElementName] is operating in a Degraded
State.
Warning
FQXSPPW0003G Failure predicted on [PowerSupplyElementName].
Warning
FQXSPPW0006I [PowerSupplyElementName] has lost input.
Warning