ThinkSystem SR665 Internal HBA/RAID Adapter Upgrade cable kit
This topic provides important information about ThinkSystem SR665 Internal HBA/RAID Adapter Upgrade
cable kit. The option package contains the following items:
Description Qty From To
1 Power cable from MB to CFF/EXP
2
RAID PWR (MB) Pwr (CFF/EXP)
2 MB to CFF RAID_2 CPU
1
PCIe6 (MB) CFF INPUT
3 G3 RAID to front SAS/SATA BP
1
C0 (RAID)
C1 (RAID)
BP2/EXP
4 G4 RAID to front SAS/SATA BP
1
C0/C1 (RAID) SAS (BP2)
HBA/RAID
5 CFF RAID to CFF EXP
1
C0 (CFF) and C1 (CFF) HBA/RAID
6 CFF RAID to front 8 x 2.5" Bay1/2
2
C0/C2 (CFF) and C1/C3
(CFF)
BP1/2
7 CFF RAID to rear 8 x 2.5" SAS/SATA /2
1
C2 (CFF) SAS0 (BP4)
8 CFF RAID to rear 8 x 2.5" SAS/SATA /1
1
C3 (CFF) SAS1 (BP4)
9 CFF EXP to rear 4 x 2.5" SAS/SATA
1
C3 EXP/C0 SAS (BP4)/SAS (BP)
10 CFF EXP to rear 4 x 2.5" SAS/SATA
1
C4 (EXP) SAS
(BP6)
11 CFF EXP to middle (2) 4 x 2.5" SAS/SATA
1
C3 (EXP) SAS (BP5) and SAS (BP6)
12 CFF EXP to front 8 x 2.5" SAS/SATA Bay1
1
C0 (EXP) SAS (BP1)
13 CFF EXP to front 8 x 2.5" SAS/SATA bay2/3
2
C1/C2 (EXP) SAS (BP2/BP3)
14 CFF EXP to middle and rear SAS/SATA BP
1
C3 (EXP) SAS (BP4) and SAS (BP5)
CFF: Custom Form Factor RAID adapter between fans and front backplane
EXP: RAID expansion adapter, next to CFF RAID adapter, between fans and front backplane
MB: motherboard
For information about installing the option product, refer to the Internal cable routing chapter in the Setup
Guide, or go to:
https://thinksystem.lenovofiles.com/help/topic/7D2W/internal_cable_routing.html.
To get the latest technical information and download device drivers and updates, go to:
https://datacentersupport.lenovo.com/us/en/products/servers/thinksystem/sr665/7d2w/downloads/driver-list.
Chapter 1 System Options 19