Table 2. Events organized by severity (continued)
Event ID
Message String Severity
FQXSPUP4002I Flash of [arg1] from [arg2] failed for user [arg3]. Informational
FQXSPUP4006I Auto promote primary XCC to backup is [arg1] by user [arg2] from
[arg3] at IP address [arg4].
Informational
FQXSPUP4007I Violation access to XCC SPI flash is detected and isolated. Informational
FQXSPUP4008I Violation access to UEFI SPI flash is detected and isolated. Informational
FQXSPUP4010I Flash [arg1] of [arg2] from [arg3] succeeded for user [arg4] . Informational
FQXSPUP4011I Flash [arg1] of [arg2] from [arg3] failed for user [arg4]. Informational
FQXSPWD0000I Watchdog Timer expired for [WatchdogElementName]. Informational
FQXSPWD0001I Reboot of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0002I Powering off system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0003I Power cycle of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0004I Watchdog Timer interrupt occurred for [WatchdogElementName]. Informational
FQXSPBR4001I Running the backup Management Controller [arg1] main application.
Warning
FQXSPCA0007J Numeric sensor [NumericSensorElementName] going high (upper
non-critical) has asserted.
Warning
FQXSPDM4002I Device [arg1] VPD is not valid.
Warning
FQXSPEA0001J Sensor [SensorElementName] has transitioned from normal to non-
critical state.
Warning
FQXSPEA0003J Link down is detected on port [arg1] of the PCIe device [arg2].
Warning
FQXSPEM4040I Dust filter measurement is completed. The airflow pathway is
obstructed, check and replace the dust filter, or remove any
obstructing object.
Warning
FQXSPEM4043I A [arg1] failure has been detected and need [arg2] to recover. Warning
FQXSPIO0014J Bus [SensorElementName] is operating in a degraded state.
Warning
FQXSPMA0001I Error Detected and Corrected for [PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
Warning
FQXSPMA0010J [PhysicalMemoryElementName] on Subsystem
[MemoryElementName] Throttled.
Warning
FQXSPMA0011G Memory Logging Limit Reached for [PhysicalMemoryElementName]
on Subsystem [MemoryElementName].
Warning
FQXSPMA0024G Sensor [SensorElementName] has asserted.
Warning
FQXSPMA4034G Health of DIMM [arg1] is in warning state and sub-state is [arg2].
Warning
FQXSPNM4010I DHCP[[arg1]] failure, no IP address assigned. Warning
FQXSPNM4032I DHCPv6 failure, no IP address assigned.
Warning
FQXSPPP4009I The measured power value exceeded the power cap value. Warning
24 ThinkSystem SR685a V3 Messages and Codes Reference