User Action:
Please check event log in xClarity Controller web interface.
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps.
2. Replace the affected Power Supply.
3. If problem persists, escalate to next level of support.
• FQXSPPW0061M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps:
1. Ensure power supply unit to meet the system spec in wattage, efficiency level and supported list.
2. Check the event log in xClarity Controller (XCC) Web GUI to the detail information to reseat/reinstall/
upgrade power supply unit.
3. If the problem still exist, please contact Lenovo support
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps.
2. Replace the affected Power Supply.
3. If problem persists, escalate to next level of support.
• FQXSPPW0063M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps until the problem is solved:
126
ThinkSystem SR850 V2 System Events Service Guide