Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps by confirming that the drive has been disabled.
2. Replace the affected disk drive that is indicated by a fault LED or the system event log.
3. If problem persists, escalate to next level of support.
FQXSPSD0002G: Failure Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: System - Predicted Failure
SNMP Trap ID: 27
CIM Prefix: PLAT CIM ID: 0168
User Action:
Replace hard disk drive 0 at the next maintenance period.
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps by confirming that drive PFA has been asserted.
2. Replace the affected disk drive that is indicated by a fault LED or the system event log.
3. If problem persists, escalate to next level of support.
FQXSPSD0002L: Drive [arg1] in the enclosure/chassis(MTM-SN: [arg2]) has been disabled due to a
detected fault.
This message is for the use case when an implementation has detected a Drive was Disabled due to fault.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0164
User Action:
Complete the following steps:
1. Check the Support Portal(http://support.lenovo.com/)for service bulletins and TECH tips and
firmware update related to your drive.
2. Check for any other RAID-related error.
3. Replace the drive.
136