Service Action:
Complete the following steps until the problem is solved:
1. Check Lenovo Support for service bulletins and Tech tips and firmware update related to drive.
2. Replace the drive.
3. If problem persists, escalate to next level of support.
• FQXSPSD0003G: Failure Predicted on drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: System - Predicted Failure
SNMP Trap ID: 27
CIM Prefix: PLAT CIM ID: 0168
User Action:
Replace hard disk drive 0 at the next maintenance period.
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps by confirming that drive PFA has been asserted.
2. Replace the affected disk drive that is indicated by a fault LED or the system event log.
3. If problem persists, escalate to next level of support.
• FQXSPSD0003I: Hot Spare enabled for [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required
Service Action:
Information only; no action is required.
• FQXSPSD0005I: Hot Spare enabled for drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
Chapter 2. XClarity Controller events 137