CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required
Service Action:
Information only; no action is required.
FQXSPSD0005L: Array [ComputerSystemElementName] is in critical condition.
This message is for the use case when an implementation has detected that an Array is Critical.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0174
User Action:
Replace the hard disk drive that is indicated by a lit status LED.
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps by confirming the RAID array is in critical condition.
2. Replace the affected disk drive that is indicated by a fault LED or the system event log.
3. Initiate a rebuild of the RAID array if does not auto-rebuild.
4. If problem persists, escalate to next level of support.
FQXSPSD0006L: Array [ComputerSystemElementName] has failed.
This message is for the use case when an implementation has detected that an Array Failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0176
User Action:
Complete the following steps:
1. Replace any hard disk drive that is indicated by a lit status LED.
2. Re-create the array.
3. Restore the data from a backup.