• FQXSPUN0023N: Sensor [SensorElementName] has transitioned to non-recoverable.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0530
User Action:
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reboot the system.
3. If the error continues, replace the system-board assembly (see hardware maintenance manual).
Service Action:
Complete the following steps until the problem is solved:
1. Review PD Steps.
2. Reduce the compute board/system in error to a minimum configuration; 1 CPU + 1 DIMM. Does the problem
still occur? Yes/No
3. No: Add CPU and/DIMMs one and a time until the error re-occurs. Consider replacing the last CPU or DIMM
that was installed that caused the error.
4. Yes: If there error/problem still exists, swap in one of the other DIMMs and/or CPUs previously removed in
step a. Proceed to add HW one piece at a time to identify the bad CPU or DIMM.
5. If the problem still exist, (trained technician only) replace compute board.
6. If problem persists, escalate to next level of support.
• FQXSPUN0026I: Device [LogicalDeviceElementName] has been added.
This message is for the use case when an implementation has detected a Device was inserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0536
User Action:
Information only; no action is required
Service Action:
Information only; no action is required.
• FQXSPUN0048I: The RAID controller in PCI slot [arg1] in optimal status.
This message is for the use case when an implementation has detected a Sensor transition to the normal
state.
172
ThinkSystem SR850 V2 System Events Service Guide