Service Action:
Complete the following steps:
1. Verify PD steps.
2. If problem persists, escalate to next level support.
FQXSFMA0047M: SPD CRC checking failed on DIMM [arg1]. [arg2]
Severity: Warning
User Action:
Complete the following steps:
1. Perform a virtual reseat or AC cycle the server.
2. If the problem returns Collect Service Data log.
3. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Review PD Steps.
2. Replace affected DIMM(s) in the channel.
3. If problem persists, Replace system board.
4. If problem persists, escalate to next level of support.
FQXSFPU0001N: An unsupported processor has been detected.
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for a firmware update required for this processor and install that update, if
applicable.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Verify PD steps.
2. Verify that this is not a system limitation.
3. Replace system board if the CPU socket is damaged.
4. If there are multiple processors, swap affected processor with another processor from a different socket.
5. If problem follows the affected processor, or this is a single processor system, replace the processor.
6. If problem persists, escalate to next level support.
FQXSFPU0002N: An invalid processor type has been detected.
Severity: Error
User Action:
Complete the following steps: