EasyManua.ls Logo

Lenovo ThinkSystem SR850 V2 - Page 244

Lenovo ThinkSystem SR850 V2
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FQXSFSR0003G: The number of boot attempts has been exceeded. No bootable device found.
Severity: Warning
User Action:
Complete the following steps:
1. Remove AC power from the system.
2. Connect at least one bootable device ot the system.
3. Connect AC power to the system.
4. Power on system and retry.
5. If the problem persists, collect Service Data logs.
6. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Review PD Steps.
2. If problem persists, escalate to next level support.
FQXSFTR0001L: An invalid date and time have been detected.
Severity: Warning
User Action:
Complete the following steps:
1. Check the XCC event logs. This event should immediately precede an FQXSFPW0001L error.
Resolve that event or any other battery related errors.
2. Use F1 Setup to reset date and time.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Review PD Steps.
2. Replace CMOS battery.
3. If problem persists then check Lenovo support site for an applicable service bulletin or firmware update that
applies to this error.
4. If problem persists, escalate to next level support.
240 ThinkSystem SR850 V2 System Events Service Guide