Table 2. Events organized by severity (continued)
Event ID
Message String Severity
FQXSPEM4015I The RAID controller detected unrecoverable error. The controller 
needs replacement.([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4016I
The RAID controller detected one or more problems. Please contact 
technical support for additional assistance.([arg1],[arg2],[arg3],[arg4], 
[arg5])
Informational
FQXSPEM4017I The RAID controller detected one or more possible configuration 
changes within the subsystem. Please check the drive LED status. If 
necessary, contact technical support for additional assistance.([arg1], 
[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4018I Enclosure/Chassis issue detected with one or more units. Please 
check the enclosure/chassis units to repair the problem.([arg1],[arg2], 
[arg3],[arg4],[arg5])
Informational
FQXSPEM4019I Connectivity issue detected with the enclosure/chassis. Please check 
your cable configurations to repair the problem.([arg1],[arg2],[arg3], 
[arg4],[arg5])
Informational
FQXSPEM4020I Fan problem detected with the enclosure/chassis. Please check the 
enclosure/chassis unit fan for correct operation.([arg1],[arg2],[arg3], 
[arg4],[arg5])
Informational
FQXSPEM4022I Enclosure/Chassis power supply has problem. Please check the 
enclosure/chassis unit power supply for correct operation.([arg1], 
[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4023I One or more virtual drive are in abnormal status that may cause 
unavailable virtual drive. Please check the event logs and if events are 
targeted to the same disk then replace the drive. If necessary, contact 
technical support for additional assistance.([arg1],[arg2],[arg3],[arg4], 
[arg5])
Informational
FQXSPEM4024I The RAID controller detected one or more possible configuration 
problem within the subsystem. Please check the event logs and if 
events are targeted to the same disk then replace the drive. If 
necessary, contact technical support for additional assistance.([arg1], 
[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4025I One or more virtual drive have problem. Please contact technical 
support to resolve this issue.([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4026I
Drive error was detected by RAID controller. Please contact technical 
support to resolve this issue.([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4027I Drive error was detected by RAID controller. Please check the event 
logs and if events are targeted to the same disk then replace the drive. 
If necessary, contact technical support for additional assistance. 
([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4028I The port [arg1] of PCIe device [arg2] at [arg3] has link [arg4]. Informational
FQXSPEM4029I All PCIe slots on [arg1] may not be functional based upon your current 
CPU population.
Informational
FQXSPEM4030I A scheduled operation on the RAID controller has encountered an 
issue. Refer to RAID Logs under Server Management, Local Storage, 
for details.([arg1],[arg2],[arg3],[arg4],[arg5])
Informational
FQXSPEM4031I SSD wear threshold setting is changed from [arg1] to [arg2] by user 
[arg3] from [arg4] at IP address [arg5].
Informational
10 ThinkSystem SR950 V3 Messages and Codes Reference