Table 3. Events organized by severity (continued)
Event ID
Message String Severity
FQXSFIO0022J PCIe Link Width has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
Warning
FQXSFIO0023J PCIe Link Speed has degraded from [arg1] to [arg2] in physical [arg3]
number [arg4].
Warning
FQXSFIO0032M PCIe Correctable Error PFA Threshold limit has been exceeded at Bus
[arg1] Device [arg2] Function [arg3]. The Vendor ID for the device is
[arg4] and the Device ID is [arg5]. The physical bay number is [arg6].
Warning
FQXSFIO0033J PCIe Link Width has degraded from [arg1] to [arg2] in physical bay
number [arg3].
Warning
FQXSFIO0034J PCIe Link Speed has degraded from [arg1] to [arg2] in physical bay
number [arg3].
Warning
FQXSFMA0012L The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2] at
address [arg3]. [arg4]
Warning
FQXSFMA0016M Memory spare copy failed. [arg1]
Warning
FQXSFMA0026G Multi-bit CE occurred on DIMM [arg1], need to restart the system for
DIMM Self-healing to attempt post package repair (PPR).
Warning
FQXSFMA0027M DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at
Rank [arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6].
[arg7]
Warning
FQXSFMA0028M DIMM [arg1] Self-healing, attempt post package repair (PPR)
exceeded DIMM level threshold [arg2] at Rank [arg3] Sub Rank [arg4]
Bank [arg5] Row [arg6] on Device [arg7]. [arg8]
Warning
FQXSFMA0030K Intel Optane PMEM [arg1] Percentage Remaining is less than [arg2]%
and still functioning.
Warning
FQXSFMA0031K Intel Optane PMEM [arg1] has reached 1% remaining spares block
and still functioning.
Warning
FQXSFMA0033M Intel Optane PMEM persistent memory interleave set has [arg1]
PMEMs(DIMM [arg2]), [arg3] DIMMs' location is not correct.
Warning
FQXSFMA0034M DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory
interleave set should be moved to DIMM slot [arg3] in sequence.
Warning
FQXSFMA0035M Intel Optane PMEM interleave set should have [arg1] PMEMs, but
[arg2] PMEMs are missing.
Warning
FQXSFMA0036M DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory
interleave set is missing.
Warning
FQXSFMA0037G Intel Optane PMEM interleave set (DIMM [arg1]) is migrated from
another system (Platform ID: [arg2]), these migrated PMEMs are not
supported nor warranted in this system.
Warning
FQXSFMA0038K All Intel Optane PMEMs could not be auto unlocked because of no
passphrase.
Warning
FQXSFMA0039K One or more Intel Optane PMEMs could not be auto unlocked
because of invalid passphrase.
Warning
FQXSFMA0040K Invalid Intel Optane PMEM configuration detected. Please verify
PMEM configuration is valid.
Warning
144 ThinkSystem SR950 V3 Messages and Codes Reference