Table 3. Events organized by severity (continued)
Event ID
Message String Severity
FQXSFIO0007M An error has been detected by the IIO on Bus [arg1]. The value of
Global Fatal Error Status register is [arg2]. The value of Global Non-
Fatal Error Status register is [arg3]. Please check error logs for
additional downstream device error data.
Error
FQXSFIO0010M An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The physical [arg6] number is [arg7].
Error
FQXSFIO0011M A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is
[arg5]. The Physical slot number is [arg6].
Error
FQXSFIO0012M A PCIe system error has occurred on Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The Physical slot number is [arg6].
Error
FQXSFIO0014J A bad option ROM checksum was detected for the device found at
Bus [arg1] Device [arg2] Function [arg3]. The Vendor ID for the device
is [arg4] and the Device ID is [arg5]. The physical slot number is [arg6].
Error
FQXSFIO0017M IFM: Error communicating with the XCC - IFM may not be deployed
correctly.
Error
FQXSFIO0019J PCIe Resource Conflict.
Error
FQXSFIO0031M An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2]
Function [arg3]. The Vendor ID for the device is [arg4] and the Device
ID is [arg5]. The physical bay number is [arg6].
Error
FQXSFMA0001M DIMM [arg1] has been disabled due to an error detected during POST.
[arg2]
Error
FQXSFMA0002M An uncorrectable memory error has been detected on DIMM [arg1] at
address [arg2]. [arg3]
Error
FQXSFMA0003K A memory mismatch has been detected. Please verify that the
memory configuration is valid. [arg1]
Error
FQXSFMA0004N No system memory has been detected. [arg1]
Error
FQXSFMA0005N Memory is present within the system but could not be configured.
Please verify that the memory configuration is valid. [arg1]
Error
FQXSFMA0008M DIMM [arg1] has failed the POST memory test. [arg2] Error
FQXSFMA0009K Invalid memory configuration for Mirror Mode. Please correct memory
configuration. [arg1]
Error
FQXSFMA0010K Invalid memory configuration for Sparing Mode. Please correct
memory configuration. [arg1]
Error
FQXSFMA0023M Error has occurred in NVDIMM flash. NVDIMM backup/restore may
not operate correctly. [arg1]
Error
FQXSFMA0024M Error has occurred in NVDIMM Supercap. NVDIMM backup/restore
may not operate correctly. [arg1]
Error
FQXSFMA0025M NVDIMM Supercap has been disconnected. NVDIMM will lose its
backup ability until this is corrected. [arg1]
Error
FQXSFMA0027K Invalid memory configuration (Unsupported DIMM Population)
detected. Please verify memory configuration is valid.
Error
146 ThinkSystem SR950 V3 Messages and Codes Reference