EasyManuals Logo

Lenze E82EV552K4C User Manual

Lenze E82EV552K4C
588 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #468 background imageLoading...
Page #468 background image
Error elimination
Error messages at the keypad or in the parameter setting program Global Drive Control
11
Troubleshooting and fault elimin ation
11.4
11.4.2
L
11.4-4
EDS82EV903-1.0-11/2002
Keypad RemedyCauseErrorPC
1)
Pt5
a
81 Time fault during parameter
set transfer
Data flow from keypad or PC interrupted, e. g.
keypad was disconnected during transfer
It is absolutely necessar y to repeat the data t ransfer or
load the Lenze setting before enabling the controller.
rSt
a
76 Faulty auto-TRIP reset More than 8 fault messages in 10 minutes Depends on the error message
sd5
a
85 Wire breakage analog input 1 Current at analog input < 4 mA at setpoint range 4
... 20 mA
Close circuit at analog input
sd7
a
87 Wire breakage analog input 2
1)
LECOM-fault number, display in parameter setting program Global Drive Control (GDC)
Show/Hide Bookmarks

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E82EV552K4C and is the answer not in the manual?

Lenze E82EV552K4C Specifications

General IconGeneral
BrandLenze
ModelE82EV552K4C
CategoryDC Drives
LanguageEnglish

Related product manuals