What to do if Lenze DC Drives motor does not rotate because wrong parameter set is active?
- TTyler DeanSep 8, 2025
If the Lenze DC Drives motor does not rotate and the wrong parameter set is active, change to the correct parameter set via terminal.

What to do if Lenze DC Drives motor does not rotate because wrong parameter set is active?
If the Lenze DC Drives motor does not rotate and the wrong parameter set is active, change to the correct parameter set via terminal.
What to do if Lenze DC Drives motor does not rotate because no motor parameter identification executed?
If the Lenze DC Drives motor does not rotate and the operating mode C0014 = '4' or '5', but no motor parameter identification has been executed, perform motor parameter identification (C0148).
What to do if Lenze DC Drives motor does not rotate because of conflicting functions assigned to the same signal source?
If the Lenze DC Drives motor does not rotate and several mutually exclusive functions are assigned to the same signal source under C0410, correct the configuration in C0410.
What to do if Lenze DC Drives motor does not rotate because of missing jumper?
If the Lenze DC Drives motor does not rotate and you are using the internal voltage source X3/20 for function modules Standard I/O, INTERBUS, PROFIBUS-DP, or LECOM-B (RS485), ensure that the jumper between X3/7 and X3/39 is present. If it's missing, jumper the terminals.
What to do if Lenze DC Drives motor does not rotate smoothly because motor underexcited or overexcited?
If the Lenze DC Drives motor does not rotate smoothly, and the motor is either underexcited or overexcited, check the parameter settings (C0015, C0016, C0014).
What to do if Lenze DC Drives motor does not rotate smoothly because of incorrect parameters?
If the Lenze DC Drives motor does not rotate smoothly, and parameters C0084, C0087, C0088, C0089, C0090, C0091, and/or C0092 are not adapted to the motor data, perform manual adaptation or identification of motor parameters (C0148).
Provides essential safety guidelines and application directives for controller installation and operation.
Details safety precautions and application specifics for Lenze low-voltage motors.
Covers conformity, approvals, climatic conditions, installation height, and mechanical design.
Details rated data for 230 V operation, including normal and increased power modes.
Covers important notes, mechanical design, and dimensions for inverter installation.
Details important notes, protection of persons, mains types, and EMC installation guidelines.
Guides users through essential checks before initiating the commissioning process.
Provides step-by-step instructions for commissioning V/f characteristic control.
Details the process for commissioning vector control, including motor parameter identification.
Covers installation, displays, functions, menu structure, and parameter operations via keypad.
Details start conditions, flying-restart circuits, and controller inhibit functions.
Explains I2t monitoring and temperature monitoring with PTC and earth-fault detection.
Covers external fault detection and reset of external faults.
Guides on detecting failures using controller LEDs and analyzing errors with the history buffer.
Describes controller responses to TRIP, message, and warning fault types.
Provides solutions for common drive maloperations like motor not rotating or smooth running.
Explains how to eliminate causes of TRIP error messages and reset them.