8
EDBSV571 EN 1.0
EN
Technical Data
2.3 Ratings
120V / 240VAC Models
Mains = 120V Single Phase (1/N/PE) (90...132V), 240V Single Phase (2/PE) (170...264V); 48...62Hz
Type
Power Mains Current Output Current Heat Loss (Watts)
Hp kW
120V
A
240V
A
Cont (In)
A
Max I
%
N1/IP31
ESV371--1S-- 0.5 0.37 9.2 4.6 2.4 200 32
ESV751--1S-- 1 0.75 16.6 8.3 4.2 200 52
ESV112--1S-- 1.5 1.1 20 10.0 6.0 200 74
NOTES:
Output Current: The Output Current Maximum (%) is a percentage of the Output Current Continuous
Amps (In) rating and is adjustable in parameter P171.
240VAC Models
Mains = 240V Single Phase (2/PE) (170...264V); 48...62Hz
Type
Power Mains Current Output Current Heat Loss (Watts)
Hp kW
240V
A
Cont (In)
A
Max I
%
N1/IP31
ESV371--2S-- 0.5 0.37 5.1 2.4 200
ESV751--2S-- 1 0.75 8.8 4.2 200
ESV112--2S-- 1.5 1.1 12.0 6.0 200
ESV152--2S-- 2 1.5 13.3 7.0 200
ESV222--2S-- 3 2.2 17.1 9.6 200
240V Single Phase (2/PE) (170...264V), 240V Three Phase (3/PE) (170...264V); 48...62Hz
Type
Power Mains Current Output Current Heat Loss (Watts)
Hp kW
1~ (2/PE)
A
3~ (3/PE)
A
Cont (In)
A
Max I
%
N1/IP31
ESV371--2Y-- 0.5 0.37 5.1 2.9 2.4 200 27
ESV751--2Y-- 1 0.75 8.8 5.0 4.2 200 41
ESV112--2Y-- 1.5 1.1 12.0 6.9 6.0 200 64
ESV152--2Y-- 2 1.5 13.3 8.1 7.0 200 75
ESV222--2Y-- 3 2.2 17.1 10.8 9.6 200 103