Function library
Function blocks
3.5.1 Absolute value generation (ABS)
3−95
l
EDSVS9332P−EXT DE 2.0
3.5 Function blocks
3.5.1 Absolute value generation (ABS)
Description
This function block converts bipolar signals to unipolar signals.
The absolute value is generated by the input signal and is provided at the output.
ABS1
ABS1-OUT
ABS1-IN
C0662
C0661
fb_abs
Fig. 3−43 Absolute value generator (ABS1)