Function library
Function blocks
3.5.47 Logic NOT
3−224
l
EDSVS9332P−EXT DE 2.0
NOT4
1
NOT4-OUT
NOT4-IN
C0847
C0846
Fig. 3−170 Logic NOT (NOT4)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
NOT4−IN d C0847 bin C0846 2 1000
NOT4−OUT d
NOT5
1
NOT5-OUT
NOT5-IN
C0849
C0848
Fig. 3−171 Logic NOT (NOT5)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
NOT5−IN d C0849 bin C0848 2 1000
NOT5−OUT d
Function
NOTx−IN1 NOTx−OUT
0 1
1 0
The function corresponds to a change from an NO contact to an NC contact in a contactor control.
NOTx−IN
NOTx−OUT
Fig. 3−172 Function of NOT when changing an NO contact to an NC contact.