Configuration
Change of the terminal assignment
2.4.4 Freely assignable monitor outputs
2−15
l
EDSVS9332P−EXT DE 2.0
2.4.4 Freely assignable monitor outputs
Use the monitor outputs X6/62 and X6/63 to output internal signals as voltage signals.
Under C0108 and C0109 the outputs can be adapted to e.g. a measuring device or a slave drive.
The most important codes can be found in the submenu: AOUT1 X6.62 or AIN2 X6.63 (analog output
1 (X6.62) or analog output 1 (X6.63))
Change assignment:
1. Select the output to be assigned to another signal (source) (e.g. C0431 for output X6/62) in the
code level.
2. Change to the parameter level with PRG. Select the signal from the indicated list which is to
be output via the monitor output.
3. If necessary, adjust an offset in the hardware under C0109
4. If necessary, the signal gain can be adapted to the hardware under C0108.
5. Repeat steps 1. to 4. to assign the second output.