Environmental condions
Climate
Storage EN 60721-3-1:1997
1K3 (-30 ... +60°C) <3 months
1K3 (-30 ... +40 °C) >3 months
Transport EN 60721-3-2:1997 2K3 (-30 ...+70 °C)
Operaon
EN 60721-3-3:1995 +
A2:1997
3K3 (-30 ...+40 °C) Operaon
Site altude
0 … 1000 m amsl
-
Without current derang
1000 … 4000 m amsl Reduce rated output current by 5 %/1000 m
Polluon
- EN IEC 61800-5-1 Degree of polluon 2
Vibraon resistance
Operaon
EN 60721-3-3:1995 +
A2:1997
3M4
Transport EN 60721-3-2:1997 2M2
Vibraon severity
A EN IEC 60034-14 - -
Electrical supply condions
Possibility of connecon to dierent types of mains power supply enables worldwide use.
The following is supported:
•
3-phase mains connecon 400 V
•
3-phase mains connecon 480 V
Type of mains power supply
TT Mains power supplies with earthed start point
Voltage against earth: max. 300 V
TN
Rated data
Motor MSEMA
063-42 080-32
Rated mains voltage V 400 480 400 480
Rated power P
rated
kW 0.476 1.361
Verstellbereich rpm -2600 ... -600 /0/ 600 ... 2600
Rated current I
rated
A 1 0.8 2.8 2.3
Rated torque M
rated
Nm 1.75 5.00
Starng torque M
a
Nm 7 20
Power factor cos ϕ 0.99
Eciency
at 75 % P
rated
% 65 73
at 100 % P
rated
% 66 74
Moment of inera J kgcm² 3.70 26.0
Weight m kg 5.9 12.5
Technical data
Rated data
Environmental condions