EasyManua.ls Logo

Lenze g500 - Residual Hazards

Lenze g500
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Residual hazards
Even if notes given are taken into consideraon and protecve measures are implemented, the occurrence
of residual risks cannot be fully prevented.
The user must take the residual hazards menoned into consideraon in the risk assessment for his/her
machine/system.
If the above is disregarded, this can lead to severe injuries to persons and damage to property!
Product
Observe the warning labels on the product!
Icon Descripon
Electrostac sensive devices:
Before working on the product, the sta must ensure to be free of electrostac charge!
Dangerous electrical voltage
Before working on the product, check if no voltage is applied to the power terminals!
Aer mains disconnecon, the power terminals carry the hazardous electrical voltage for the me given next
to the symbol!
High leakage current:
Carry out xed installaon and PE connecon in compliance with EN 61800−5−1 or EN 60204−1!
Hot surface:
Use personal protecve equipment or wait unl the device has cooled down!
Protecon of persons
The product does not provide safety-related funcons.
-
A higher-level safety system must be implemented.
-
Addional monitoring and protecve equipment complying with the safety regulaons applicable in
each case must be used.
The power terminals may carry voltage in the switched‐o state or when the motor is stopped.
-
Before working, check whether all power terminals are deenergised.
Careful earthing in the marked posions of the components must be carried out.
Risk of burns may be caused by hot surfaces!
-
Provide for a protecon against accidental contact.
-
Use the personal protecve equipment or wait unl the components have cooled down completely!
-
Prevent contact with ammable substances.
There is a risk of injury due to rotang parts.
-
Before working on the drive system, ensure that the motor is at a standsll.
There is a danger of unintenonal starng or electrical shocks!
Installed brakes are no fail-safe brakes.
-
torque may be reduced by disrupve factors that cannot be inuenced such as ingressing oil.
Motor protecon
Design with plug:
-
Never disconnect the plug when energised! Otherwise, the plug can be destroyed.
-
Switch o power supply prior to disconnecng the plug.
Parameterise the product so that it will be switched o aer some seconds of operaon with I > I
N
, espe-
cially if there is a danger of blocking.
-
The installed overload protecon does not prevent an overload under any condions.
The fuses are no motor protecon.
Too high torques cause a fracon of the motor sha.
-
The maximum torques according to catalogue must not be exceeded.
Lateral forces from the motor sha may occur.
-
Align the shas of motor and driven machine exactly to each other.