EasyManua.ls Logo

Lenze g500 - Malfunctions

Lenze g500
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Malfuncons
Fault Possible causes Remedy
Type Message
F RFID read error (RFIR) NFC communicaon interrupted 1. Connect and disconnect mains.
2. Repeat acon.
3. If the error occurs again, please
contact the Lenze Service.
F RFID write error (RFIW)
F RFID data CRC invalid (PS02) NFC communicaon interrupted 1. Load default seng.
2. Connect and disconnect mains.
3. Rewrite parameter set.
F RFID data version invalid (PS04) Incompable soware version Update Lenze App or EASY Starter.
F Missing mains phase (SU02) A mains phase of a three-phase sup-
ply has failed. Reliable detecon from
an ulisaon > 50 % rated motor
power.
Check mains connecon.
Check fuses.
F DC bus overvoltage (OU) DC-bus voltage too high
Increase deceleraon ramp.
Reduce speed for great regenera-
ve loads.
Use brake resistor.
W Electronics warning temperature (OH4) Lacking or insucient cooling.
Drive close to being disconnected due
to overtemperature (OH1)
Ambient temperature too high.
Check cooling.
Clean cooling ribs.
Ambient temperature must be in the
permissible range.
F Electronics overtemperature (OH1)
F Electronics overload (Ixt ) (OC9) The Ixt overload test has been trig-
gered
Motor load too high.
Load cycles not complied with.
Increase deceleraon ramp.
Reduce Imax.
Check dimensioning.
F Electronics overcurrent (OC11) Overcurrent limitaon acve
Reduce motor load.
Increase deceleraon ramp.
F Motor overcurrent (OC7) The maximum current monitoring
funcon has been triggered.
Reduce motor load.
F Motor short circuit (OC1) Short circuit in the motor phases Reset error. If the error occurs again
during restart, please contact the
Lenze Service.
F Motor earth fault (OC2) A motor phase has earth contact
F Motor overload I2xt (OC6) Motor thermally overloaded
Reduce motor load.
Check seng of the I2xt monitor-
ing funcon.
Increase deceleraon ramp.
F Brake resistor overload I2xt (OC12) Too frequent and too long braking
processes
Increase deceleraon ramp.
Lenze Smart motor without brake
resistor: DC-bus voltage too high
Reduce regenerave load.
Use brake resistor.
Increase deceleraon ramp.
F Internal error (DH69) Various Reset error. If the error occurs again
during restart, please contact the
Lenze Service.
F Internal error (DF01)
...
Internal error (DF13)
Diagnoscs and fault eliminaon
Malfuncons
64