Safety instructions
Residual hazards
2
13
Lenze ¯ MA 12.0013 ¯ 3.0
Motor protection
¯ Installed thermal detectors are no full protection for the machine.
If required, limit the maximum current, parameterise the controller such that it
will be switched off after some seconds of operation with I > I
N
, especially if
there is the danger of blocking.
Installed overload protection does not prevent an overload under any
conditions.
¯ Installed brakes are no fail−safe brakes.
The torque can be reduced due to disruptive factors that cannot be influenced,
e.g. by ingressing oil due to a defect shaft sealing ring on the A side.
¯ Fuses are no motor protection.
Use current−dependent motor protection switches at average operating
frequency.
Use installed thermal detectors at high operating frequency.
¯ In the case of permanent−magnet motors, too high torques cause
demagnetisation.
The maximum torques according to catalogue must not be exceeded.
¯ If deviations from normal operation occur, e.g. increased temperature, noise,
vibration, determine the cause and, if necessary, contact the manufacturer. If in
doubt, switch off the motor.
¯ Design with plug:
Never disconnect plug when energised! Otherwise, the plug can be destroyed.
Switch off power supply and inhibit controller prior to disconnecting the plug.
Fire protection
¯ Fire hazard
Prevent contact with flammable substances.