Error messages
Possible causes and remedies
12.2 Possible causes and remedies
This chapter contains all PROFINET error messages in numerical order of the error number.
Possible causes and remedies as well as responses to the error messages are described in
detail.
Short overview of the PROFINET error messages
( 68)
PROFINET: Exist. conn. to 8400 lost [0x01bc3100]
PROFINET: Memory: No access [0x01bc5531]
PROFINET: Memory: Read error [0x01bc5532]
PROFINET: Memory: Write error [0x01bc5533]
PROFINET: Restart by watchdog reset [0x01bc6010]
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble ; Warning locked Warning Information
Cause Remedy
Internal communication to the Control Unit has been
interrupted.
Inverter Drive 8400 motec has been switched off.
Incorrect wiring of Communication Unit.
Switch on Inverter Drive 8400 motec.
Check Communication Unit for correct wiring.
Send device with error description to Lenze.
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble ; Warning locked Warning Information
Cause Remedy
Access to memory was not possible. Send device with error description to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter could not be read. Download application again (including module).
Send device with error description to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter could not be written. Download application again (including module).
Send device with error description to Lenze.
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
; None System fault : Fault Trouble Quick stop by trouble ; Warning locked Warning Information
Cause Remedy
Device is damaged. Send device with error description to Lenze.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze L-force 8400 motec E84DGFCR Series and is the answer not in the manual?

Lenze L-force 8400 motec E84DGFCR Series Specifications

General IconGeneral
BrandLenze
ModelL-force 8400 motec E84DGFCR Series
CategoryConference System
LanguageEnglish

Related product manuals