Safety engineering
Safety functions
Safe PROFIsafe connection
1
1.3
1.3.5
1.3-16
EDS94AYAD EN 2.2
Error number Description
64 The Profisafe target address set does not comply with the parameter
F_Dest_Add.
65 The F_Dest_Add parameter has the invalid value 0x0000 or 0xFFFF.
66 The F_Source_Add parameter has the invalid value 0x0000 or 0xFFFF.
67 The F_WD_Time parameter has the invalid value 0 ms.
68 TheF_SILparameterdoesnothavethevalidvalue0...2.
69 The F_CRC_Length parameter does not have the valid value 2.
70 The version of the PROFIsafe parameter set is wrong.
71 CRC1 error