EasyManua.ls Logo

Lenze L-force EDK94AZHN26

Lenze L-force EDK94AZHN26
104 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Rated data
2
EDK94AZHN26 DE/EN/FR/ES/IT 1.2
35
l
H1_Daten−Maße_mm
Rated data
Input data
Voltage Frequency Current [A]
Number
of
phases
Type [V] [Hz] max. +45 °C
max. +55 °C
E94AZHN0026 400/500 50/60 0.75/0.75 0.61/0.61 1
Temperature in the control cabinet
Output data
Voltage Frequency Current [A]
Number
of
phases
Type [V] [Hz] max. +45 °C
max. +55 °C
E94AZHN0026 180/225 0 (DC) 0.75/0.75 0.61/0.61 1
Temperature in the control cabinet
Area Values
Input voltage AC 400 V (320 ... 550 V), 45 ... 65 Hz
Output voltage DC 180 V With mains voltage of AC 400 V
Brake current 0.1 ... 0.61 A
Cable protection Recommendation: 5 A, tripping characteristic "B" or "C"
Control input DI
Signalling output DO
Control voltage
DC 24 V, PLC level
HIGH
LOW
DC +15 ... 30 V
DC 0 ... +3 V
Control current
Input 5 ... 10 mA
Output 5 ... 50 mA
Protective function Protected against polarity reversal up to DC 60 V
Max. connectable cable
cross−section
2.5 mm
2
AWG 12
Maximum cable length 150 m

Table of Contents

Related product manuals