Electrical installation
Connection data
4
EDK94AZHN26 DE/EN/FR/ES/IT 1.2
41
l
H1_E_INST−−−−(DUMMYSEITEVOR)−−−
Control connection
Terminal X117 Labelling Description
DI Digital input
GI GND digital in
DO Signalling output
24V 24−V supply by safely separated power supply unit
(SELV/PELV)
SSP94A6117
GND GND digital out
Terminal data
Conductor cross−section Tightening torque
[mm
2
] [AWG] [Nm] [lb−in]
Flexible
0.5 ... 2.5 20 ... 12 Spring terminal
With wire end
ferrule
Stripping length or contact length: 8 mm
Digital output DO
State Description
HIGH No fault
LOW Fault
l Supply voltage of the motor holding brake is missing
l Motor holding brake is not connected
l Brake cable is defective
Open circuit
Short circuit
l Supply voltage of the motor brake control is missing