6  Electrical installation
Term inal  box 
Feedback system
6.4  Term inal box
1
Note!
Open the holes on the underside o f the  knock out term inal  box w hen the 
cover is closed.
EN
Cable glands and term inal studs fo r the pow er term inal box
Motor type / Power connection
motor size
Screwed connections Terminal Terminal board
Cable
cross-section
[mm2]
Stripping length 
[mm]
Tightening 
torque [Nm]
Threaded
bolt
Tightening 
torque [Nm]
MCA
,  , 
,
1 x M20 x 1.5 + 1 x M16 x 1.5 0.08 ... 2.5 10 ... 11
2)
19, 21 1 x M32 x 1.5 + 1 x M25 x 1.5 0.2 ... 10 10 ... 11
2)
20 2 x M20 + 2 x M 25 + 2 x  M32 2.5 ... 16 18 ... 20
2)
22
1 x M40x1.5 + 1 x M50x1.5 + 
1 x M20x1.5 + 1 x M16x1.5
10 ... 35 18 3,2
26
1 x M50 x 1.5 + 1 x M63 x 1.5 + 
1 x M20 x 1.5 + 1 x M16 x 1.5
M12 15.5
MQA 20 2 x M20 + 2 x M 25 + 2 x  M32 2.5 ... 16 18 ... 20
2)
22
1 x M40x1.5 + 1 x M50x1.5 + 
1 x M20x1.5 + 1 x M16x1.5
10 ... 35 18 3.2
26
1 x M50 x 1.5 + 1 x M63 x 1.5 + 
1 x M20 x 1.5 + 1 x M16 x 1.5
M12 15.5
MCS 09, 12,
14D,
14H,
14L15,
14P14,
19F15,
19J15
2 x M20 + 2 x M25 + 2 x M32
0.08 ... 2.5 1) 10 ... 11
2)
14L32,
14P32,
19F13,
19J30,
19P
0.2 ... 10 10 ... 11
2)
MDFQA 160 2 x M63 x 1.5 + 1 x M16 x 1.5 M12 15.5
MDdKS
056,
071
1 x M20 x 1.5 + 1 x M16 x 1.5 0.08 ... 2.5 10 ... 11
2)
Tab. 1  Cable glands and connecting terminals
1)  4 mm2 without wire end ferrule
2)  Spring terminal
32
Lenze • BA 33.0006 • 3.0