Technical data
Standards and operang condions
Conformies and approvals
More informaon and cercates of approval can be found under
g500 + m850 bevel geared motors
Europa
Country Conformity/approval Product representaon
European Union CE CE mark
Eurasian Economic Union (EAEU) EAC EAC mark
Great Britain UKCA UKCA mark
America
Country Conformity/approval Product representaon
Canada CSA
cULus mark
USA UL
Asia
Country Conformity/approval Product representaon
China -
CEL mark
EFUP mark
Protecon of persons and device protecon
Protecon class
-
EN IEC 60529,EN IEC
60034-5
IP54
Informaon applies to the mounted and ready-
for-use state
IP65
Temperature class
- EN IEC 60034-1 F (155 °C) Insulaon system
Permissible voltage
-
IEC 60034-18-41 IVIC C At 500 V
IEC/TS
60034-25:2007
Limit curve A Of the pulse voltage
EMC data
Noise emission
- EN IEC 60034-1 A nal overall assessment of the drive system is indispensable
Noise immunity
- EN IEC 60034-1 A nal overall assessment of the drive system is indispensable
Environmental condions
Climate
Storage EN 60721-3-1:1997
1K3 (-20 ... +40 °C) >3 months
1K3 (-20 ... +60 °C) <3 months
Transport EN 60721-3-2:1997 2K3 (-20 ... +70 °C)
Operaon
EN 60721-3-3:1995 +
A2:1997
3K3 (-10 ... +40 °C) Operaon, without brake
3K3 (-15 ...+40 °C) Operaon without brake, forced venlated
3K3 (-20 ...+40 °C) Operaon without brake, self-venlated
Site altude
0 … 1000 m amsl
-
Without current derang
1000 ... 2000 m. amsl Reduce rated output current by 5 %/1000 m
Air humidity
- - Average relave humidity 85 % Without condensaon