Diagnoscs and fault eliminaon
Malfuncons
If faults occur during the operaon of the drive, the table below helps you to idenfy the
causes. If it is not possible to remedy the fault using the measures listed, please contact the
Lenze service department.
Error Possible cause Remedy
Drive is not running Voltage supply interrupted Check connecon
Faulty electrical connecon Check external voltage supply.
Load too high Reduce load
Check assignment drive - machine
Motor runs, gearbox does not Coupling components are missing or defecve Check mounng
Gearbox is defecve Inform Lenze Service
Clutch disengaged Engage the clutch
Unusual running noises Overload Reduce load
Check assignment drive - machine
Excessive temperature Overload Reduce load
Inadequate heat dissipaon Improve cooling air supply, clean gearbox / motor
Lack of lubricant Top up lubricant according to regulaons
Vibraons, noise Loose xing elements Tighten xing elements
Shrink disc connecon is spinning Correct screw ghtening torque has not been reached
-
Insucient number of passes, not all screws are
ghtened correctly.
Specicaons for assembly, dimensions and material
must be observed
Machine sha and hollow sha bore not suciently
degreased
Wrong component part dimensions
-
Fits, roughnesses
Yield point of machine sha material is too low
-
Re > 300 N/mm2 required
Fricon factors are too low
-
Surface roughness Rz ≤ 15 µm required
The shrink disc itself has been degreased so that the
screws and the bevels are dry. Due to incorrect fricon
factors, the shrink disc cannot be ghtened correctly.
Oil is leaking Wrong oil level for the applied mounng posion Check mounng posion (see nameplate) and oil level
Inially slight leakage at the sha seal Opmum sealing condions only arise aer the
running-in phase
Overpressure due to lacking venlaon Install venlaon according to the mounng posion
Overpressure due to polluted venlaon Clean venlaon
Worn-out sha sealing rings Check condion of sealing lip contact area, repair if
necessary.
Cover / ange screws are loose Check that the xing screws are ghtly fastened.
Connue to monitor the gearbox
Oil discharge at the gearbox
venlaon unit
Incorrect oil level for the mounng posion applied
and/or incorrect posion of venlaon unit
Check mounng posion (see nameplate) and oil level
Check posion of venlaon unit
Use oil compensaon reservoir
Diagnoscs and fault eliminaon
Malfuncons
51