EasyManua.ls Logo

Lenze MP 800 DVI - Sicherheitshinweise für die Installation nach UL

Lenze MP 800 DVI
88 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sicherheitshinweise
Sicherheitshinweise für die Installation nach UL
2
6
MA_ELx0xx DE/EN/FR/ES/IT 2.0
2.1 Sicherheitshinweise für die Installation nach UL
Original − Englisch
Approval
Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File
Number E236341)
Ratings
ƒ Input 24 V DC, 65 W
ƒ For use on an isolated power supply rated 24V DC 4A max.
ƒ Max. ambient temperature 40°C
ƒ Max. surrounding temperature 50 °C
ƒ Optional communication ratings:
RS232−Connection (APL and DPL version only): max. 3 A
USB−Connection (DVI version only): max. 1 A
PS/2−Connection: max. 1 A
VGA−Connection (APL version only): max. 4 A
FBAS−Connection (APL version only): max. 4 A
DVI−Connector (DVI version only): max. 4 A
DPL−Connection (DVI version only): max. 4 A
External Power Supply for DVI/USB Extender: max. 4 A
Video−DSUB Connection for DVI/USB Extender: max. 4 A
Data−DSUB Connection for DVI/USB Extender: max. 4 A
ƒ Environmental ratings: If these devices are mounted into a door or front
cover of an enclosure: Type 1 Enclosure.
Warnings!
Conditions of acceptability
ƒ These devices are for Type 1 front panel mounting only.
ƒ The external power supply connection is suitable for field wiring.
An isolated power supply rated 24 V DC, 4 A max. must be used.
Field Wiring Markings
Wiring Terminal MSTB 2,5/3−STF−5,08:
ƒ Use Copper Wire only.
ƒ AWG 18 ... AWG 12 (0.82 mm
2
... 3.3 mm
2
)
ƒ Torque 5...7 lb−in (0.5 ... 0.6 Nm)