www.lesterelectrical.com 1 00870E
LESTRONIC II BATTERY CHARGER
MODEL 07850 TYPE 36LC25-8ET
Specifications
AC Input:
105-128 Volts AC, 60 Hertz, single-phase, 13 Amps Max
DC Output:
36 Volts DC, 25 Amps tapering to 8 Amps at 45 Volts DC
Connections:
8½ ft. DC cord with connecting plug standard; optional plugs and cord lengths
available
Dimensions:
10-1/6 H x 8-11/16 W x 9-1/2 D
Mounting:
Set on shelf, wall mount with keyholes, or hang from ceiling securely.
PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS
For correct operation of the equipment, it is important to read and be familiar
with this entire manual before installing and operating the charger.
DO NOT DISCARD THIS MANUAL AFTER READING.
LOOK FOR THIS SYMBOL TO POINT OUT SAFETY PRECAUTIONS. IT MEANS:
BECOME ALERT—YOUR SAFETY IS INVOLVED.
IF YOU DO NOT FOLLOW THESE
SAFETY INSTRUCTIONS, INJURY OR PROPERTY DAMAGE CAN OCCUR.
Features
Patented electronic timer monitors battery state of charge and automatically turns charger off at full charge.
Line voltage compensation achieved by flux oscillator ciruit applied to battery charger for high reliability "Minute Man" missile
standby applications. Compensates automatically for AC supply voltage variations. Supply voltage variation + 10% from
nominal = + 1% maximum battery voltage variation, decreasing to + ½% at finish rate with constant electrolyte temperature.
No taps or rate controls to set.
Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.
Silicon diodes with inherent surge protection operation at a conservative percentage of their rating.
Convection cooled design for maximum reliability and minimum maintenance.
INTRODUCTION
The Lestronic II battery charger is designed to
recharge deep-cycle, lead acid batteries. A
ferroresonant transformer is used to provide a highly
reliable, line compensating unit with a minimum of
moving parts, designed for long, trouble-free service.
A patented electronic timer turns the charger on and
off automatically. This electronic timer determines
full charge of the batteries by measuring the rate at
which the battery voltage increases during charge.
When the voltage stops rising, the battery is fully
charged and the charger turns off.
INITIAL INSTALLATION
The AC line to which the charger is to be connected
must be capable of supplying 15 amperes to this
charger.
CAUTION: TO REDUCE THE RISK OF FIRE,
USE THIS CHARGER ONLY ON CIRCUITS
PROVIDED WITH A MAXIMUM OF 20 AMPERE
BRANCH CIRCUIT PROTECTION (CIRCUIT
BREAKER OR FUSE), IN ACCORDANCE WITH
THE NATIONAL ELECTRICAL CODE, ANSI/NFPA
70, AND ALL LOCAL CODES AND ORDINANCES.

Question and Answer IconNeed help?

Do you have a question about the Lester 07850 and is the answer not in the manual?

Lester 07850 Specifications

General IconGeneral
BrandLester
Model07850
CategoryBattery Charger
LanguageEnglish

Summary

Specifications

AC Input

105-128 Volts AC, 60 Hertz, single-phase, 13 Amps Max.

DC Output

36 Volts DC, 25 Amps tapering to 8 Amps at 45 Volts DC.

Features

Electronic Timer Operation

Monitors battery state of charge and automatically turns charger off at full charge.

Line Voltage Compensation

Achieved by flux oscillator circuit for high reliability, compensating for AC supply voltage variations.

Grounding Instructions

Equipment-Grounding Conductor

Proper connection of the equipment-grounding conductor to reduce risk of electric shock.

Normal Operation

Connecting Power Supply

Connect power supply cord to a 115 volt, 60 Hertz circuit to a properly grounded outlet.