Commissioning and configuration
Leuze electronic BCL 548i 149
TNT 35/7-24V
Input data length
1 byte
Output data
None
Remarks
The following bits are constantly updated, i.e. they are updated immediately after the
respective event occurs:
Reading gate state
Further results in the buffer
Buffer overflow
Waiting for acknowledgement
All other flags refer to the currently output decoding result.
If the input data is reset to the init. value (cf. "Module 30 – Data formatting" on page 152),
the following bits are reset:
•New result
•Result state
All others remain unchanged.
Data reset behavior:
Upon data reset (see Module 10 – Activations), the input data is deleted, except for the
reading gate status and the two toggle bits.