Questions and Answers

  • G
    gonzalezdeborahAug 18, 2025
    What to do if Leuze electronic Barcode Reader cannot read code?
    • T
      timothy27Aug 18, 2025
      If your Leuze electronic Barcode Reader fails to read codes, it could be due to several reasons. First, ensure the code quality is sufficient and that the entire code is within the laser line. Second, verify that the code is enabled in the code table, checking the type and length entries. Finally, address excessive reflections by increasing the angle of the laser beam to more than 10° with respect to vertical.
  • S
    Steven RhodesAug 20, 2025
    Why is no communication possible with Leuze electronic Barcode Reader?
    • C
      courtney06Aug 20, 2025
      If you are experiencing communication issues with your Leuze electronic Barcode Reader, there are several potential causes. First, verify the wiring to ensure it is correct. Second, confirm that the correct interface is selected using the BCLconfig tool. Lastly, check the protocol settings in both the BCL 8 and the BCLconfig tool, or switch the BCL 8 to service mode to ensure they are aligned.
  • K
    Kevin LynchAug 22, 2025
    How to fix Leuze electronic Barcode Reader when status LED is flashing red?
    • C
      carolyn18Aug 22, 2025
      If the status LED on your Leuze electronic Barcode Reader is flashing red, this indicates a device warning. To resolve this, query the diagnostic data within the device and take the necessary actions based on the results, or try resetting the device.
  • A
    Anna MarshallAug 26, 2025
    What to do if Leuze electronic Barcode Reader status LED is flashing orange?
    • A
      Alexis GayAug 26, 2025
      If the status LED on your Leuze electronic Barcode Reader is flashing orange, it means a service operation is currently active. You can reset this by either resetting the device or interrupting the supply voltage.
  • M
    Mario CamposAug 28, 2025
    Why is the status LED on my Leuze electronic Barcode Reader continuous red?
    • R
      rachel72Aug 28, 2025
      If the status LED on your Leuze electronic Barcode Reader shows a continuous red light, it indicates a serious internal error that prevents the device from functioning. In this case, send the device in for testing.
  • K
    Krista LeAug 30, 2025
    How to troubleshoot Leuze electronic Barcode Reader when status LED is off?
    • J
      James BradleyAug 30, 2025
      If the status LED on your Leuze electronic Barcode Reader is off, it indicates that no supply voltage is connected to the device. Check the supply voltage to resolve this issue.
  • C
    Carolyn FoxSep 2, 2025
    What to do if Leuze electronic BCL 8 S 2 has no communication?
    • E
      Erin ThompsonSep 2, 2025
      If your Leuze electronic Barcode Reader isn't communicating, there are several potential causes. First, check the wiring to ensure it is correct. Second, verify that the correct interface is selected in the BCLconfig tool. Finally, confirm that the protocol settings in the BCL 8 and BCLconfig tool match, or switch the BCL 8 to service mode.
  • N
    Nicole WoodsSep 4, 2025
    Why is my Leuze electronic BCL 8 S 2 Barcode Reader not reading codes?
    • J
      James CharlesSep 4, 2025
      If your Leuze electronic Barcode Reader isn't reading codes, consider these potential causes: the code quality might be insufficient, so improve the code quality and ensure the entire code is within the laser line. Also, the code might not be enabled, so check the entries in the code table (type and length). Finally, excessive reflections could be the issue, so increase the angle of the laser beam to more than 10° with respect to vertical.
  • K
    Kimberly ScottSep 7, 2025
    What does it mean if the status LED is flashing red on Leuze electronic Barcode Reader?
    • S
      sclarkSep 7, 2025
      If the status LED on your Leuze electronic Barcode Reader is flashing red, it indicates a device warning. To resolve this, query the diagnostic data in the device, take the necessary actions based on the findings, or try resetting the device.
  • C
    Christina GordonSep 9, 2025
    How to fix Leuze electronic BCL 8 S 2 Barcode Reader when status LED is flashing orange?
    • J
      Jonathan AndersonSep 9, 2025
      If the status LED on your Leuze electronic Barcode Reader is flashing orange, it means a service operation is active. You can reset the service operation by resetting the device or interrupting the supply voltage.

Leuze electronic BCL 8 S 2 Series Specifications

General IconGeneral
TypeBarcode Reader
ModelBCL 8 S 2 Series
Light SourceLED
Wavelength650 nm
Protection ClassIP 65
InterfaceRS 232, RS 422, USB, Ethernet
Code TypesCode 39, Code 128, EAN, UPC
Supply Voltage10 V to 30 V DC
Operating Temperature0°C to +50°C
Storage Temperature-20°C to +70°C
Weight200 g

Related product manuals