Accessories / Order Designation
Leuze electronic BCL 8 29
TNT 35/7-24V
Figure 5.2: Electrical connection MA 8-01
5.3.3 MA 8-01 - BCL - connecting the BCL 8 to the MA 8-01
Figure 5.1: MA 8-01 - Pin assignment BCL
Attention!
Protection class IP 67 is achieved only if the connectors and caps are screwed into place!
The BCL 8 is connected to the MA 8-01 via the connection cable KB 008-1000/2000/3000
(AA/AR). The voltage supply is connected via the PWR IN HOST/RS 485 socket.
Switching input
Switching output
BPS (5-pin socket, A-coded)
Pin Name Remark
1VIN
Supply voltage for BCL 8
approx. +5.2VDC
2 TXD RS 232 transmission line
3 GND Supply voltage 0VDC
4 RXD RS 232 receiving line
5
SWIN/
SWOUT
Programmable switching input/output of the
BCL 8
Thread FE Functional earth (housing)
M12 socket
(A-coded)

Table of Contents