Important Parameters
48 BCL 8 Leuze electronic
Notice!
In general, the remaining parameters must not be changed. In the worst case, this could cor-
rupt the reading result!
10.2 Output tab
Figure 10.3: Output tab
Notice!
The structure of this message string is depicted symbolically in the preview window.
Output header
Select from the options listed below. The output header is sent in a
separate message before the read result.
Label header
The Label header is set directly before the code data.
Label footer
The label footer is appended directly to the code data.
Message mode
Selects whether the bar codes read are sent in concatenation or
separately as individual strings.
Text in the case of
misreading
This character is set for each unrecognized bar code. Multiple charac-
ters (=string) may be entered here. Up to 20 characters are possible.
Features
Set the desired formatting modes and formatting characters as nec-
essary.