Important Parameters
Leuze electronic BCL 8 53
TNT 35/7-24V
10.6 Sensor tab
Figure 10.8: Sensor tab
Notice!
If the switch-off delay is activated, the parameter "pulse duration" should be "0".
Attention!
Depending on wiring, either a switching input or a switching output is available on the BCL 8.
Inverted
Here, the input level can be inverted.
Enable
Switching input enabled or disabled.
Debounce time
This time period must lapse until the trigger signal is regarded as
valid.
Start-up delay
The trigger signal is passed on delayed by the specified time period.
Pulse duration
If the value is higher than "0": duration of the activation, regardless of
how long the trigger signal has been present.
Switch-off delay
After the end of the trigger signal, the pulse is extended internally by
this time period.
Function
Event that is started when the switching input is activated.