EasyManua.ls Logo

Leuze electronic BCL 8 S 2 Series - MA 8-01 - PWR in HOST;RS 485 - Voltage Supply and RS 485; Figure 5.1: MA 8-01 - Pin Assignment PWR in HOST;RS 485

Leuze electronic BCL 8 S 2 Series
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories / Order Designation
Leuze electronic BCL 8 27
TNT 35/7-24V
Electrical connection MA 8-01
5.3.1 MA 8-01 - PWR IN HOST/RS 485 - voltage supply and RS 485
Figure 5.1: MA 8-01 - Pin assignment PWR IN HOST/RS 485
Attention!
Protection class IP 67 is achieved only if the connectors and caps are screwed into place!
Electrical data
Interface type RS 485
Service interface without MA 8-01 connected:
RS 232 with default data format,
9600Bd, 8 data bits, no parity, 1 stop bit
with MA 8-01 connected:
RS 485 replaces RS 232
Switching input /
switching output
1 switching input, 1 switching output, each is programmable
switching input: 10 30VDC
switching output: I
max
= 500mA
output voltage = operating voltage
Operating voltage 10 30VDC
Power consumption max. 0.5W
PWR IN HOST/RS 485 (5-pin plug, A-coded)
Pin Name Remark
1VINPositive supply voltage: +10 +30VDC
2B (N)RS 485 receive/transmit data B-line (N)
3GNDSupply voltage 0VDC
4A (P)RS 485 receive/transmit data A-line (P)
5FEFunctional earth
Thread FE Functional earth (housing)
3
21
4
5
A (P) GND
VIN
FE
B (N)
PWR IN
HOST/RS485
M12 plug
(A-coded)

Table of Contents

Related product manuals