Installation
Leuze electronic BCL 8 35
TNT 35/7-24V
6.3 Connection
Attention!
The BCL 8 bar code reader is completely sealed and cannot be opened.
Do not try to open the device under any circumstances, as this voids both protection class
IP 67 and the warranty.
Before connecting the device please ensure that the supply voltage matches the value print-
ed on the nameplate.
Connection of the device and maintenance work while under voltage must only be carried
out by a qualified electrician.
The power supply unit for the generation of the supply voltage for the BCL 8 and the corre-
sponding connector units must have a secure electrical insulation according to IEC 60742
(PELV). For UL applications: only for use in class 2 circuits according to NEC.
Take care to connect the protective conductor correctly to the housing screen. Error-free
operation is only guaranteed when the device is properly earthed.
If faults cannot be corrected, the device should be removed from operation and protected
against possible commissioning.
6.3.1 Connecting the BCL 8
BCL 8 pin assignment
Figure 6.3: BCL 8 pin assignment
Wiring description
Table 6.1: Wiring description BCL 8
Pin 1 +5V DC Operating voltage 5VDC
Pin 2 RS 232 TxD TxD signal line of the RS232 interface
Pin 3 GND Operating voltage 0VDC / reference ground
Pin 4 RS 232 RxD RxD signal line of the RS232 interface
Pin 5 SW IN/OUT Switching input or switching output
Top view of the BCL 8 connector