6.3.3 Line lengths
The following maximum line lengths to be used must be observed:
Table 6.2: Line lengths
Notice!
The RS 232 connection between BCL 8 and host must not exceed a total of 10m.
6.4 Disassembling, packing, disposing
Repacking
For later re-use, the device is to be packed so that it is protected against shocks and damp-
ness. Optimal protection is achieved when using the original packaging.
Notice!
Electrical scrap is a special waste product! Observe the locally applicable regulations re-
garding disposal of the product.
Connection Interface Max. cable length Shielding
BCL 8 direct RS 232 < 3m necessary
BCL 8 – MA 8.1 RS 232 < 3m necessary
BCL 8 – MA 8-01 RS 232 < 3m necessary
MA 8.1 – host RS 232 < 10m necessary
MA 8-01 – host RS 485 < 25m necessary
Switching input/output < 10m not necessary