Accessories / Order Designation
28 BCL 8 Leuze electronic
5.3.2 MA 8-01 - SW IN/OUT - switching input and switching output
Figure 5.1: MA 8-01 - Pin assignment SW IN/OUT
Attention!
Protection class IP 67 is achieved only if the connectors and caps are screwed into place!
Notice!
The switching input/switching output are programmed via the parameters in the BCLconfig
configuration software. For more information see chapter 10.6 and chapter 10.8, from
page 53 onwards.
Attention!
If you use a sensor with a standard M12 connector, then please note the following:
Use only sensors on which the switching output does not lie on pin 2 or sensor cables
on which pin 2 is not assigned. Otherwise, the switching output is not protected against
feedback on the switching input. If the inverted sensor output lies on pin 2, erroneous behav-
iour of the switching output will result.
SW IN/OUT(5-pin socket, A-coded)
Pin Name Remark
1VOUT
Voltage supply for sensors
(VOUT identical to VIN at PWR IN)
2SWOUTSwitching output
3GNDGND for the sensors
4SWINSwitching input
5FEFunctional earth
Thread FE Functional earth (housing)
1
23
4
5
SWIN VOUT
GND
FE
SWOUT
SW IN/OUT
M12 socket