Electrical connection
Leuze electronic MLD 300, MLD 500 60
Table 7.12: Selection of the operating mode and other functions
7.3.6 Operating mode 6 (partial muting):
• Start/restart interlock is selected
• Muting timeout extension is selectable
• If a second muting signal is supplied e.g. by a control, this can also be connected here at the 8-pin
plug.
PIN Connection
Operating mode selection
20 V
7 +24 V
4 Bridge to pin 1
Other functions
1 RES (via start button at +24 V)
3 EDM (without EDM: +24 V; with EDM: 0 V via feedback circuit)
5 OSSD2
6 OSSD1
8 Muting-enable / M-TO (muting-timeout extension)
Figure 7.17: Connection example MLD 330, MLD 530 (transmitter-receiver system): muting-enable
(transceiver connected in an analogous manner)
0V
0V
MLD300, MLD500 - T
n.c.
1
74
3
-W1
2
-W2
7
3
54
5
-W1
1
6
-W2
2
31
-A2
4
3
21
-A1
6
PE
+24V
0V
+24V
PE
0V
MS2
n.c.
5
n.c.
MLD330, MLD530 - R
+24V
+24V
EDM
RES
OSSD2
OSSD1
8
M-EN/TO
0V
MS2
4
3
21
MS1
5
RES/LMP
+24V
SH
SH
3
-W3
SH
-W3
1
42
“M”
x1
x2
-MS1
+-
-MS2
+-
8
5
Safety-PLC
or
Safety Relay
FE
FE
FE